TS-RMS-Credit-12

Tycon Systems Remote Management System (RMS) Access Credit 12 Month Pack.
Enables remote connection to RMS for 1 device for 12 months or 12 devices for 1 month.

Spec Sheet
User Guide





Original price was: $36.00.Current price is: $29.95.

Volume Pricing

  • Quantity Price
  • Pcs 1000 - ∞ $29.95

Summary

  • Your Price:
  • Subtotal:

  • Ships in 1-2 days
  • No Risk Guarantee
  • 2-3 Year Warranty

Description

The 1 Year (12 months) subscription to Tycon® RMS Management Portal provides a comprehensive and efficient solution for managing all RUT241 devices deployed in the field. This user-friendly portal offers a single interface that allows you to monitor device status, make configuration changes, update software, set up VPN access to your external devices, and perform quick remote access to check and reboot devices, among other functionalities.

Simplified Device Management

Centralized Interface: The RMS Management Portal simplifies the management of multiple devices by offering a centralized interface. This feature allows you to efficiently monitor and control all RUT241 units deployed in various locations. By having all devices accessible through a single interface, you can streamline your management processes and improve overall efficiency.

Remote Access and Control: With the RMS Management Portal, you can perform quick remote access to check and reboot devices. This capability ensures that you can address issues and make necessary adjustments without the need for physical presence, saving time and resources. Additionally, the portal allows you to set up VPN access to external devices, enhancing the security and accessibility of your network.

Efficient Monitoring and Updates

Device Status Monitoring: The portal enables you to monitor the status of your devices in real-time. By having up-to-date information on each unit, you can proactively address potential issues and ensure optimal performance. The RMS Management Portal also allows you to make configuration changes and update software, ensuring that your devices are always running the latest firmware and settings.

Requirements for Connection

RMS Access Credits: To connect a Cellular/WiFi Router to the Tycon Systems Remote Management System (RMS), you need RMS Access Credits. Each router requires 1 credit per month for monitoring. This requirement ensures that you have the necessary resources to maintain efficient and effective management of your devices.

Flexible Credit Packs

Pack of 12 Credits: Tycon Systems sells these credits in packs of 12. This means you can either keep 1 device connected for 12 months or 12 devices connected for 1 month. The credits come as codes that you add to your account, allowing you to distribute them as needed. This flexibility ensures that you can manage your devices according to your specific requirements, optimizing the use of your credits.

Summary

In summary, the 1 Year (12 months) subscription to Tycon® RMS Management Portal offers a comprehensive solution for managing RUT241 devices in the field. With its centralized interface, remote access capabilities, real-time monitoring, and the need for RMS Access Credits, this portal provides the tools and resources needed for efficient device management. Explore the full range of Tycon® products to find the perfect solutions for your remote management needs. Experience the superior quality and functionality that the Tycon® RMS Management Portal brings to your installations.

All Tycon Systems Remote Monitoring System

Wikipedia – Remote Monitoring System

FAQs

Frequently Asked Questions

Where can I access the RUT241 manual and programming examples?

You can find the detailed Wiki here: https://wiki.teltonika-networks.com/view/RUT241

Below is an image of the Wiki page contents:

What SIM cards can I use with the RUT241?

Any SIM card with a 4G data plan will work.

What is the default username and password for the RUT241?

The username is ‘admin’. Each RUT241 has a unique password which is printed on the bottom of the unit.

What is the default IP address for the RUT241 web interface?

The default IP address is 192.168.1.1

There are 3 flashing LEDs next to the RUT241 power connector. What does it mean?

This means the SIM card is not detected. Check the SIM card placement and make sure the contacts are clean.

How do I setup a VPN connection to the RUT241 so I can access my connected devices?

VPN Configuration for Remote Management System
Download the PDF file

Log into your rms.tyconsystems.com account.

First, you will need to add a device.

Make sure the device you want to add is powered on and has a connection to the internet.

Click on the ADD button.

For the device series, select RUT.

Enter a name for your device. This can be anything you choose.

Enter the 10-digit serial number. This is printed on the bottom of the device.

Enter the 12-digit MAC Address. This is printed on the bottom of the device.

Enter the password. If you have not changed the password, enter the one printed on the bottom of the device.

Click on Submit.

An status window will appear and tell you if it was successful.

If the device status shows a red triangle, the password is incorrect. Click on the red triangle and enter the password again.

If the status for the device shows a black circle (not activated), it may take a minute or two for it to turn green.

Click on VPN hubs then click ADD.

Give the VPN a name and select a location from the drop-down menu, then click CREATE.

Click on the VPN you just created.

Click on Clients.

You will need to add an RMS user and an RMS device. Click on ADD.

Click the plus symbol to add the RMS user, then click CONFIRM.

Click on the download button to download the VPN Configuration file. We will use this later.

Select RMS Devices, then click on the plus symbol next to the device you want to add, then click CONFIRM.

Select Routes and enable LAN forwarding.

Click on ADD ROUTE. You can use Auto Scan to find devices that are connected to the LAN, or you can enter them manually.

To use Auto Scan, click on the Device box. Then select the device you want to scan. 

Click on SCAN DEVICE.

Select the device you want to add, then click on ADD.

To add a device manually, select Manual. Enter the IP address, Netmask, and Client.

After making these changes the VPN Hub needs to be restarted. Click on RESTART HUB.

The VPN is now configured in RMS. To test it, download and install OpenVPN Connect at openvpn.net/client/

In OpenVPN Connect, click ULOAD FILE.

Now you will need the .ovpn configuration file that you downloaded earlier.

Drag the .ovpn file to OpenVPN window or select it by clicking BROWSE.

Click CONNECT.

Now you can test the connection by entering the IP address in a web browser.

How can you connect to the RUT241 to configure it?

You can connect to the RUT241 over WiFi, with an ethernet cable to a computer, or via rms.tyconsystems.com.

How can I test the wireless signal strength on the RUT241?

The RUT241 shows the signal strength in the user interface or at rms.tyconsystems.com.

Reviews

There are no reviews yet

Be the first to review “TS-RMS-Credit-12”

Join Our Waitlist We will inform you when the product arrives in stock. Please leave your valid email address below.
RMS management portal
TS-RMS-Credit-12

Volume Pricing

  • Quantity Price
  • Pcs 1000 - ∞ $29.95

Summary

  • Your Price:
  • Subtotal: