How Can We Help?
-
EZ-Bridge®
- Are the EZ-Bridge systems shipped complete with everything I need?
- Best method/procedure to follow for first time installs of the EZ-Bridge?
- Can I get some help on QOS settings using WISPOS firmware?
- Can I have a router on both sides of the EZ-Bridge® link?
- Can I power a second device off my EZ-Bridge-LT+?
- Can I power your EZ-Bridge products from a standard PoE Switch?
- Can I Use the Second Ethernet Port to Link 2 Separate Access Points Together?
- Can the EZ-Bridge be mounted indoors?
- Can the EZ-Bridge® be used with VLANs?
- Do I need to be an engineer or technical person to install and operate the EZ-Bridge?
- EZ-Bridge LT+ TyconOS Wiki
- How can I connect two separate networks across an EZ-Bridge Ultra?
- How Can I Determine If My EZ-Bridge Antenna System is Working?
- How can I know if my bridges are communicating?
- How can I secure SSH and Telnet on the EZ-Bridge
- How can I setup a Repeater on an EZ-Bridge LT or LT+ running WISPOS software?
- How critical is line-of-sight when using the EZ-bridge.
- How do I access the EZ Bridge’s Web Interface?
- How do I access the EZ-Bridge® to change settings?
- How Do I Download and Install the Discovery Tool?
- How do I reconfigure my EZBR-0214+ for side A and B firmware
- How do I reset the EZ-Bridge® to factory defaults if I can’t open the unit’s web page?
- How do I set a Static IP address on my EZ Bridge Antenna?
- How do I set up the EZ Bridge?
- How do I turn on ping watchdog to automatically reboot the EZ-Bridge Ultra antennas?
- How do I use the EZ Bridge as a Wi-Fi access point?
- How many IP Cameras can I use with my EZ-Bridge LT2+ or LT5+ wireless link?
- How to adjust multiple bridges distance optimization
- How to change the transmit channel on an EZ-Bridge Ultra?
- I can’t open the EZ-Bridge® unit’s web page with my browser
- Is it better to use a 2.4GHz or 5GHz EZ-Bridge?
- Is it possible only to buy receiver end if I am already using EZ Bridge LT+ product?
- My EZ-Bridge was working but now it keeps dropping connection or performance has degraded. What could be the problem?
- My TyconOS/Ultra Discovery Tool Does Not Run!
- Status page explanation for the EZ-Bridge® (EZBR-0214+ and EZBR-DUAL-AC)
- What changes are required to the EZ-Bridge setup to get the system up and running?
- What changes should I make to the EZ-Bridge when changing to a Multipoint system?
- What do I need to supply when installing the EZ-Bridge® system?
- What if I don’t have good line-of-sight between my locations? How critical is line of sight?
- What if my EZ-Bridge LT+ is bricked? Can I recover it via TFTP?
- What is the bandwidth / speed capability of the different EZ-Bridge® models?
- What is the maximum range of the different EZ-Bridge® units
- What is the optimum signal strength dBm for best performance?
- What makes the HD model different?
- Which Ethernet port on EZ-Bridge-LT+ do I plug into?
- Will my speed slow down at extended distances?
- Will the EZ-Bridge work with my Linksys, D-link, router etc.?
- Show Remaining Articles (32) Collapse Articles
-
RemotePro®
- Are the solar systems shipped complete with everything I need?
- Can I add more devices to my RemotePro system without increasing the panels and batteries?
- Can I lengthen the cable between the solar controller and the solar panels?
- Can I use automotive batteries for solar systems?
- How can I add a grid or generator powered battery charger to my RemotePro system with MPPT solar controller?
- How can I add a padlock to my ENC-ST-23x14x1 enclosure?
- How can I tell if I have a bad battery?
- How do you calculate Autonomy of a battery backup system?
- How high should I install my solar panel and enclosure?
- How long will it take to charge my battery bank with a battery charger?
- How long will my battery backup power my equipment? How much autonomy should I expect?
- How much sun does my RemotePro® need?
- How to calculate how much solar panels I need to support my equipment?
- I have my system hooked up but I’m not getting the correct voltage out of the controller, what’s wrong with it?
- RemotePro® and UPSPro® Battery Care
- RemotePro® and UPSPro® Troubleshooting
- What differences can I expect when switching my batteries to LiFePO4?
- What differences can I expect when switching my batteries to LiFePO4?
- What hardware comes in my TPSM-80×4-UNI solar mount? The hardware included in the TPSM-80×4-UNI is as follows:
- What information do you need to help me size a system?
- Where can I find a rackmount for my RPSTL/ENC-STL enclosure? Are there 2U or 4U rackmounts available for Tycon Large Enclosures?
- Where can I find my Peak Sun Hours?
- Which systems come with a pole?
- Why does the load output of my solar controller keep shutting down?
- Show Remaining Articles (9) Collapse Articles
-
MobileSolarPro®
-
UPSPro®
- How can I add a padlock to my ENC-ST-23x14x1 enclosure?
- How can I tell if I have a bad battery?
- How do you calculate Autonomy of a battery backup system?
- How long will it take to charge my battery bank with a battery charger?
- How long will my battery backup power my equipment?
- RemotePro® and UPSPro® Battery Care
- RemotePro® and UPSPro® Troubleshooting
- What differences can I expect when switching my batteries to LiFePO4?
- What differences can I expect when switching my batteries to LiFePO4?
- Where can I find a Rack Mount extension for my UPSPro STL Enclosures?
-
Cellular Router
- How can I test the wireless signal strength on the RUT241?
- How can you connect to the RUT241 to configure it?
- How do I setup a VPN connection to the RUT241 so I can access my connected devices?
- There are 3 flashing LEDs next to the RUT241 power connector. What does it mean?
- What is the default IP address for the RUT241 web interface?
- What is the default username and password for the RUT241?
- What SIM cards can I use with the RUT241?
- Where can I access the RUT241 manual and programming examples?
-
TPDIN®
- Accessing Data and Controlling Relays on TPDIN-Monitor-WEB2 via HTTP
- Communicating with TPDIN-Monitor-WEB via TELNET
- Email setup information for TPDIN®
- How can I change my TPDIN-Monitor-WEB2 relays to Normally Closed (NC)
- How can I enable or disable relay functions in the TPDIN-Monitor-WEB2 via Linux scripting?
- How can I reset my TPDIN® product to factory defaults?
- How do I login to the TPDIN-SC48-20?
- How many characters for username and password in the TPDIN® products?
- I cannot send email from my TPDIN® series product?
- I was updating the firmware on the TPDIN-Monitor-WEB2 and now I can’t access the unit?
- My real time clock isn’t updating on my TPDIN®
- My WEB3 is connected to the MPPT solar controller with an RS485 serial cable but the current readings are all zero on the MPPT display and in the WEB3 MPPT page
- My WEB3 is connected to the MPPT solar controller with an RS485 serial cable but the current readings are all zero on the MPPT display and in the WEB3 MPPT page
- My WEB3 is connected to the MPPT solar controller with an RS485 serial cable but the current readings are all zero on the MPPT display and in the WEB3 MPPT page.
- Saving Power via Time of Day and Periodic Power Cycle Control – TPDIN-Monitor-WEB
- Unlicensed Timeout
- What do the error codes in the log file mean?
- What does the log entry “System Init *V2.3.5 WDT was triggered” mean?
- What network port do the TPDIN® products communicate on?
- Where can I get replacement 4 pin connectors for TPDIN® series product?
- Why am I seeing erroneous shunt current readings on my TPDIN-Monitor-WEB2 and TPDIN-Monitor-WEB3?
- Why can’t I open the TPDIN® web pages with my browser even though my computer is on the same subnet?
- Show Remaining Articles (7) Collapse Articles
-
Power Over Ethernet (PoE)
- Are Tycon PoE Switches with SFP fiber ports single, dual or multimode fiber?
- Can I use two or more units of the TP-SW4G-2SFP / TP-SW8G-2SFP in the same network?
- DC to DC Converter – Where does the FG wire connect and where does VIN- wire connect, shouldn’t they be wired together?
- Factory Reset Instructions for TP-MS616, TP-MS308, TP-MS316, TP-MS324
- How do I change the Hostname (sysName) of the TP-SW4G-2SFP or TP-SW8G-2SFP?
- How do I control the PoE ports on my TP-SW4G-2SFP or TP-SW8G-2SFP managed PoE switch using SSH?
- How do I control the PoE ports on my TP-SWxG-2SFP PoE switch using SNMP?
- MS3xx and MS6xx reset password to factory default
- NTP Time not Working or updating on my TP-SW4G-2SFP and TP-SW8G-2SFP
- What are the Differences Between Passive and Active PoE?
- What do the LEDs on the TP-DCDC-1256GD-VHP indicate?
- What does the VIN1+, VIN2+, VIN-, and FG mean on my DC to DC converter?
- What is the default IP, Username and Password for the TP-SWxG-2SFP PoE switches?
- Where can I find a PoE chart that shows different types of PoE standards?
- Where can I get the replacement green connectors for my Tycon PoE Products?
- Where can I get those green wire terminal connectors?
- Show Remaining Articles (1) Collapse Articles
-
Solar Charge Controllers
- I have a Tycon MPPT solar charge controller. My batteries are wired for 24V, but they are so low the controller thinks they are 12V batteries and won’t charge them
- My WEB3 is connected to the MPPT solar controller with an RS485 serial cable but the current readings are all zero on the MPPT display and in the WEB3 MPPT page
- My WEB3 is connected to the MPPT solar controller with an RS485 serial cable but the current readings are all zero on the MPPT display and in the WEB3 MPPT page
- Procedure for toggling the LOAD in the Firmware
- What differences can I expect when switching my batteries to LiFePO4?
- What differences can I expect when switching my batteries to LiFePO4?
-
BreezePro®
-
ProWeatherStation®
- Can I hook the ProWeatherStation up to a MAC?
- Can I power the display console from AC power?
- Can I publish my ProWeatherStation data online?
- Can I shorten or extend the sensor cables?
- Can I store data on my computer?
- Can the Display Back light be programmed to stay on?
- Can the ProWeatherStation support multiple Consoles?
- Do I need a computer to use the Pro Weather Station?
- Do I need to be an engineer or technical person to install and operate the ProWeatherStation?
- Do I need to plug in the ProWeatherStation?
- How can I send TP2700WC WeatherSmart data to my server?
- How do I Clear the Rain Values on the TP2700WC Weather Station?
- How do I upload my ProWeatherStation readings to WeatherCloud.net?
- How far can the controller be from the sensor array?
- Is the ProWeather Station® Compatible with third party software?
- My anemometer is freezing up during icy weather
- My Pro Weather Station was damaged during a storm. Do you sell replacement parts?
- My rain gauge has frozen
- My temperature is reading too high during the day
- The display changed on my TP3000WC Wireless Weather Station
- The rain gauge is recording rain when it’s not raining
- The rain gauge stopped recording rain
- The remote sensor is not transmitting to the display console
- The remote transmitter stopped working in cold weather
- The sensor array changed on my TPW3000WC, the anemometer is now on top. Why was this changed?
- What is the battery life of the Solar Powered Sensor?
- Where can I find my TP2700WC WeatherSmart data file?
- Show Remaining Articles (12) Collapse Articles
-
Miscellaneous
- Can Tycon® Provide me with a .csv file so my stock can update regularly?
- Is Tycon® in compliance with the EU’s General Data Protection Regulations?
- What are IP Ratings?
- What is Tycon’s Drop Ship Policy?
- What is Tycon’s Return and Warranty Policy?
- Where can I find Tycon’s Letter of Export Compliance?
< All Topics
MS3xx and MS6xx reset password to factory default
PostedOctober 10, 2024
UpdatedOctober 10, 2024
Please follow the instruction as below and reset the password to default.
- Turn off the unit, disconnect any Ethernet cables attached to the module.
- Press and hold S1 switch (on the left of the RJ45) and turn on the unit
- After 6 seconds, release S1 and then the unit should revert back to default settings as below:
IP: 192.168.2.1
Gateway: 192.168.2.1
Username: admin
Password: system
- Follow the manual’s RJ45 remote control port section settings, change the factors as below and then start to use.
TCP control: server mode protect timeout set to 0
UART control: Baudrate set to 9600
Table of Contents