TP-SC24-40N-MPPT

40A MPPT Solar Chrg, 12/24V, 20A Load, Neg Gnd

Spec Sheet
User Guide





$249.95

326 in stock

Summary

  • Your Price:
  • Subtotal:

  • Ships in 1-2 days
  • No Risk Guarantee
  • 2-3 Year Warranty

Features

  • Solar Charge Controller
  • MPPT Temperature Compensated Charging
  • Fully Automatic Operation
  • LCD Displays: Battery Volts, Battery Temp, Battery Level, Load Current and Solar Current
  • Autoranging 12V or 24V Battery Arrays
  • Multimode Load Operation – 5 selectable modes
  • Automatic 30day Battery Equalization
  • Conformal Coated Electronics for Environmental Protection
  • TVS lightning protection, Industrial Temperature Range
  • Low self consumption <1W

Applications

  • Remote Power Systems
  • Solar Lighting
  • Solar Power Applications

Description

The Tycon Solar™ TP-SC24-40N-MPPT solar controllers ensure efficient and reliable battery charging in various solar power systems. These advanced MPPT (Maximum Power Point Tracking) temperature compensated battery charging controllers optimize performance with the included battery temperature probe cable.

Versatile and Auto-Ranging Controllers

Auto-Ranging for 12V and 24V Battery Systems: The controllers auto-range to accommodate both 12V and 24V battery systems, offering versatility for a wide range of applications. This flexibility makes them suitable for small residential setups as well as larger industrial installations.

Compatibility with Various Battery Types

Charging Multiple Battery Types: The TP-SC24-40N-MPPT controllers charge Flooded, AGM, GEL, or Lithium batteries. Additionally, they include a USER setting for customizable battery charge settings, allowing you to tailor the charging process to your specific battery requirements.

Integral LCD Display for Monitoring

Real-Time System Monitoring: The integral LCD display provides real-time information on Battery Voltage, Battery Capacity, Charging Capacity, Battery Temperature, Load Current, and Solar Current. This comprehensive display enables effective monitoring and management of your solar power system.

Remote Monitoring and Control

RS232 Interface for Bluetooth Connectivity: The controllers include an RS232 interface to connect with the Tycon #TP-SC-BT1 Bluetooth adapter (not included). By utilizing this configuration and the available Android or iOS mobile app, you can remotely monitor and control the solar controller, enhancing convenience and control.

Summary

In summary, the Tycon Solar™ TP-SC24-40N-MPPT solar controllers offer advanced and versatile solutions for efficient battery charging in solar power systems. With auto-ranging for 12V and 24V battery systems, compatibility with multiple battery types, an integral LCD display for real-time monitoring, and remote control capabilities through Bluetooth connectivity, these controllers deliver comprehensive and reliable performance. Explore the full range of Tycon Solar™ products to find the perfect solutions for your solar power needs. Experience the superior functionality and efficiency that the TP-SC24-40N-MPPT solar controllers bring to your installations.

All Tycon Systems Solar Charge Controllers

Wikipedia – Solar Charge Controller

Technical Information

Ship Weight5.16 lbs
Ship Dimensions12 × 9 × 6 in

FAQs

Frequently Asked Questions

What differences can I expect when switching my batteries to LiFePO4?

LIT is a battery settings mode.  When switching to LIT, the S parameters should be the same as the previous default settings.

When battery voltage falls below 10V the battery BMS disconnects the battery discharge. As soon as there is PV voltage the battery BMS connects the charge and discharge. We recommend the customer set the LOAD Output turnoff at 11V so tha load disconnects before the battery BMS disconnects the discharge.

 

We recommend that you just leave the parameters set to AGM Lead Acid. This is how the Lithium battery BMS is designed. The AGM Lead Acid settings in the charge controller are compatible with the battery BMS.

You won’t see voltage spikes when connected to the battery (BMS), even if the battery BMS disconnects the discharge.  No firmware updates are available or needed to switch from AGM lead acid to lithium.

Procedure for toggling the LOAD in the Firmware?

Having physical access to the TPDIN-WEB3 Monitor and log into  it.

Select the MPPT tab

What you need to do now is to make sure the enable Load Toggle is selected

At this point you will toggle the load to off then back to On then uncheck the Enable Toggle Load box.

This makes changes to the firmware in the charge controller so now power down your controller – disconnect solar charging then disconnect the batteries by removing the fuse

Wait 1 minute then reconnect the batteries and verify everything comes back on including your load. If everything is back on then reconnect your solar.

My WEB3 is connected to the MPPT solar controller with an RS485 serial cable but the current readings are all zero on the MPPT display and in the WEB3 MPPT page

The ground between the V- load output on the MPPT solar controller and the TPDIN-Monitor-WEB3 V- needs to be isolated for the MPPT controller to sense the currents properly.

A TP-DCDC-1224 DCDC converter can be used to isolate the power and solve this issue.

I have a Tycon MPPT solar charge controller. My batteries are wired for 24V, but they are so low the controller thinks they are 12V batteries and won’t charge them

The MPPT charge controllers by default are set for 12V/24V auto detect. Using the keys on the front of the unit go into the settings and set for 24V battery instead of 12/24 auto detect. Save the setting. Power down the unit by disconnecting the solar and then battery. Power up the unit. It should power up in 24V battery mode. Re-connect the solar input.

Reviews

There are no reviews yet

Be the first to review “TP-SC24-40N-MPPT”

Join Our Waitlist We will inform you when the product arrives in stock. Please leave your valid email address below.
Solar Charge Controller
TP-SC24-40N-MPPT

326 in stock

Summary

  • Your Price:
  • Subtotal: